Unico UPC-80F-1 Single Outlet Installation Kit (for Fiberglass Duct) - Accessories - Unico - High Velocity hvac

Unico UPC-80F-1 Single Outlet Installation Kit (for Fiberglass Duct)

$123.30

Unico UPC-80F-1 Single Outlet Installation Kit (for Fiberglass Duct)

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Product Description

The UNICO SYSTEM? sound attenuator tubing is supplied in 12-ft (3.6-m) lengths for branch runs between 5 and 12 ft (1.3 to 3.6-m). The attenuator tubing is sold in kits and include all the necessary componentsto complete a duct run from the plenum to the conditioned space. For branch runs over 12 ft, use at least a 3-ft (1-m) sound attenuator (UPC-26C) coupled to the aluminum core supply tubing (UPC-25)
Each UPC-80F-1 (for Fiberglass Duct) Single Outlet Installation Kit Includes:
  • 1 ? 12 ft. (3.6 m) Insulated Attenuator tubing (UPC-26C)
  • 1 ? Supply Outlet Terminators (UPC-56B)
  • 2 ? Toggles and screws (UPC-51)
  • 1 ? Winter Shutoff plugs (UPC-42)
  • 2 ? Scrim core clamps (UPC-53B)
  • 2 ? Aluminum core clamps, black (UPC-52)
  • 1 ? Coupling with tape rings (UPC-38)
  • 1 ? Takeoff balancing cap, either 15, 35, or 50 percent reduction
  • 1 ? UPC-23B Fiberglass Takeoff

Installation
First, determine the location of the outlet. The outlet may be placed in the ceiling, floor, or sidewall. The best place is the corner, 5 inches (13 cm) from each wall. If that is not possible or practical, anywhere out of the traffic pattern is acceptable.

For floor outlets be sure to install an outlet screen (UPC-88) to prevent objects from falling into the duct.

For sidewall outlets, position the outlet well above headheight.

In most cases, except for very high ceilings, they can be 4 to 5-inches (10 to 13-cm) below the ceiling. For good air circulation they should be no higher than about 12-feet (4-m) above the floor level.

After the location is determined a hole must be cut (if necessary) and the duct routed from the plenum to the outlet location.

The attenuator tubing may be cut to any length but not less than 3 ft (1 m).

When installing the supply tubing follow these rules:
1. Use as few bends as possible.
2. If bends are necessary, provide a generous bend radius. The minimum radius is 6 inches (15 cm).
3. Support the supply tubing every 4 ft (1.2 m).
4. Be careful not to tear or puncture the supply tubing outer jacket.

For more installation instructions click on Manuals and download the full installation manual.



Sound Attenuator Tubing

Additional Information

SKU UPC-80F-1
Manufacturer Unico
Price 123.30

Contact Us

Contact Information

Write Your Own Review

You're reviewing: Unico UPC-80F-1 Single Outlet Installation Kit (for Fiberglass Duct)

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Price
Value
Quality
PayPal BillMeLater Discover Visa Mastercard AmEx PayPal